Failure Modes and Get Outs

 

Lots of people hark on about how rebreather can fail easily and kill you instantly. Here I've tried to list ALL the possible failure modes and how you can get out of them. All this is covered in your training and will become second nature. In fact ALL failures are possible to easily escape from providing you monitor the unit and do your pre dive checks

I am also only covering problems unique to the Inspiration as we still have all the normal diving problems to cope with but these are covered on lots of other sites. Please let me know if I've missed anything

There does seem to be a lot of things that can go wrong at first glance, but most of these will never happen if you do your pre-dive checks. Your training will teach you how to prevent and deal with these. If it didn't then please let me know

 

Oxygen Problems

Oxygen Cylinder Empty
Oxygen Cylinder Switched Off
Oxygen First Stage Failure
Oxygen First Stage Over Pressure
Oxygen Hose Leaks
Oxygen Solenoid Stuck Open
Oxygen Solenoid Stuck Closed
Oxygen Manual Injector Failure
Wrong Gas in Oxygen cylinder

Diluent Problems

Diluent Cylinder Empty
Diluent Cylinder Switched Off
Diluent First Stage Failure
Diluent First Stage Over Pressure
Diluent Hose Leaks
Diluent Manual Injector Failure
Alternate Air Source Free Flow
Wrong Gas in Diluent cylinder

Electronics Problems

Battery Low
Battery Failure
Battery Bounce
Handset Failure
Loose Connection to Sensor
Handsets Switched off

Sensor Problems

Single Cell Failure
Two Cell Failure
Condensation On Face
Pressure Unequalisation

Scrubber Problems

Scrubber Exhausted
Scrubber Bypass

Physical Problems

Loop Flood
BC Failure
Harness Failure

top....

 

Oxygen Cylinder Empty

Cause

Tut, tut, Who forgot to fill that cylinder! Or diving with not enough O2 for the dive. Maybe a leak somewhere, but you notice bubbles on a rebreather

Symptoms
Surface

Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding. Oxygen contents gauge showing empty

Dive

Failure to hold set point. Low O2 Alarm sounding. Oxygen contents gauge showing empty

Recovery action during Dive

Urgent. Bail out to open circuit or diluent flush and fly unit in semi closed mode

Preventative action

Check the cylinders contents during the pre-dive checks

top....

 


Oxygen Cylinder Switched Off

Cause

Lack of brain power and failure to do pre-dive checks. This should not happen, but it has claimed lives

Symptoms
Surface

Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding. Oxygen contents gauge showing empty

Dive

Failure to hold set point. Low O2 Alarm sounding. Oxygen contents gauge showing empty

Recovery action during Dive

Urgent. Open O2 valve, ready to bail out to open circuit or diluent flush and fly unit in semi closed mode

Preventative action

Check the cylinders contents during the pre-dive checks

top....

 


Oxygen First Stage Failure

Cause

Wear or structural failure. Overpressure valve fitted may blow or unit may jam

Symptoms
Surface

Failure to calibrate. Failure to hold set point during pre-breathe. Low or high O2 Alarm Sounding. Oxygen contents gauge showing empty or audible air loss from cylinder

Dive

Failure to hold set point. Low or high O2 Alarm sounding. Oxygen contents gauge may show empty. Bubbles in water

Recovery action during Dive

Urgent. Bail out to open circuit or diluent flush and fly unit in semi closed mode

Preventative action

Pre-dive checks. Oxygen Interstage pressure checks when servicing

top....

 


Oxygen First Stage Over Pressure

Cause

Bad servicing, or wear of first stage

Symptoms
Surface

Only if battery low. Solenoid can fail to fire before low battery warning given. Hence Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding

Dive

Only if battery low. Solenoid can fail to fire before low battery warning given. Hence Failure to hold set point during pre-breathe. Low O2 Alarm Sounding

Recovery action during Dive

Urgent. Bail out to open circuit or diluent flush and fly unit in semi closed mode

Preventative action

Check interstage pressure during servicing and use fresh batteries

top....

 


Oxygen Hose Leaks

Cause

Wear, bad servicing

Symptoms
Surface

Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding. Oxygen contents gauge showing low or audible air loss from cylinder

Dive

Failure to hold set point. Low  O2 Alarm sounding. Oxygen contents gauge may show empty. Bubbles in water

Recovery action during Dive

Urgent. Bail out to open circuit or diluent flush and fly unit in semi closed mode

Preventative action

Pre-dive checks

top....

 


Oxygen Solenoid Stuck Open

Cause

Corrosion, Bad servicing, salt crystals or contaminates in unit. High Interstage pressure. Low Battery

Symptoms
Surface

Failure to calibrate. Failure to hold set point during pre-breathe. High O2 Alarm Sounding. Counter lungs full

Dive

Failure to hold set point. High O2 Alarm sounding. Excessive buoyancy. Can hear solenoid injecting at all times

Recovery action during Dive

Urgent. Close O2 valve.  Bail out, or diluent flush. Option to fly manually using O2 valve or to go semi closed

Preventative action

    Regular service. Lube and ensure solenoid clean, Check mesh filter above solenoid. Fresh Batteries

top....

 


Oxygen Solenoid Stuck Closed

Cause

Corrosion, Bad servicing, salt crystals or contaminates in unit. Low battery. High interstage pressure

Symptoms
Surface

Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding.

Dive

Failure to hold set point. Low O2 Alarm sounding

Recovery action during Dive

Urgent. Fly unit manually using manual O2 injector. Consider bail out

Preventative action

Regular service. Lube and ensure solenoid clean, Check mesh filter above solenoid. Fresh batteries

top....

 


Oxygen Manual Injector Failure

Cause

Bad maintenance. Failure to plug hose on properly

Symptoms
Surface

Failure of pre dive checks

Dive

Loss of gas from loop, flooding of loop.

Recovery action during Dive

Urgent. Reconnect Hose or rescrew injector down. Bail out if loop flooded

Preventative action

Pre-Dive checks

top....

 

Wrong Gas in Oxygen cylinder

Cause

Nitrox fill or gas other than 100% oxygen

Symptoms
Surface

Failure to calibrate (maybe). failure to hold set point. Lungs full

Dive

Failure to hold set point (maybe), Excessive buoyancy and injector function

Recovery action during Dive

Bail out (you don't know what you are breathing)

Preventative action

ALWAYS analyse your gasses after a fill. You'd be amazed how many places don't give a 100% fill, or nowadays, how many air fills aren't

Analysing and labelling On these two fills one is 96% and the other 99.8%. I always analyse and label my gases myself. Never trust a shop

top....

 

Diluent Cylinder Empty

Cause

Someone forgot to fill it, or a bad leak

Symptoms
Surface

Failure of pre-dive checks, Diluent contents gauge reads zero

Dive

Lung squeeze on descent, unable to inject diluent. Auto Air out not functional. Dry suit inflate not functional

Recovery action during Dive

Plug in a reserve gas supply. Inflate lungs with manual O2 inject if above 6m

Preventative action

Pre-dive checks

top....

 


Diluent Cylinder Switched Off

Cause

Silly mistake

Symptoms
Surface

Failure of pre-dive checks, Diluent contents gauge reads zero

Dive

Lung squeeze on descent, unable to inject diluent. Auto Air out not functional. Dry suit inflate not functional

Recovery action during Dive

Open valve

Preventative action

Pre-dive checks

top....

 


Diluent First Stage Failure

Cause

Wear or structural failure

Symptoms
Surface

Failure of pre-dive checks, Diluent contents gauge reads zero

Dive

Lung squeeze on descent, unable to inject diluent. Auto Air out not functional. Dry suit inflate not functional

Recovery action during Dive

Plug in a reserve gas supply. Inflate lungs with manual O2 inject if above 6m

Preventative action

    Service correctly and Pre-dive checks

top....

 


Diluent First Stage Over Pressure

Cause

Wear or structural failure. Bad adjustment

Symptoms
Surface

Auto air free flow, BC inflation

Dive

Auto air free flow, Excessive buoyancy in BC

Recovery action during Dive

Shut down diluent valve. Manually operate when needed (Shouldn't need to surface). Consider bailout if alternate supply

Preventative action

Service correctly and pre-dive checks

top....

 


Diluent Hose Leaks

Cause

Wear. Bad servicing

Symptoms
Surface

Failure of pre-dive checks. Audible gas escape. Diluent contents decreasing

Dive

Audible gas escape. Diluent contents decreasing

Recovery action during Dive

Abort dive

Preventative action

Pre-dive checks and servicing

top....

 


Diluent Manual Injector Failure

Cause

Bad maintenance. Failure to plug hose on properly

Symptoms
Surface

Failure of pre dive checks

Dive

Loss of gas from loop, flooding of loop.

Recovery action during Dive

Urgent. Reconnect Hose or rescrew injector down. Bail out if loop flooded

Preventative action

Pre-Dive checks

top....

 

Wrong Gas In Diluent Cylinder

Cause

Cylinder filled wrongly

Symptoms
Surface

None with normal pre-dive checks

Dive

Problems maintaining Setpoint during descent

Recovery action during Dive

Abandon dive, of connect alternate diluent source (Not likely to notice during dive)

Preventative action

Analyse ALL gasses prior to use. Once unit is calibrated you can check the diluent O2 content by doing a diluent flush. This should be added as part of the pre-dive tests

top....

 


Alternate Air Source Free Flow

Cause

Dirt or high diluent interstage pressure

Symptoms
Surface

Failure of pre-dive checks. Audible gas loss

Dive

Audible gas loss and bubbles

Recovery action during Dive

Disconnect Auto air, or try shaking to reseat things. Consider aborting dive

Preventative action

Service equipment and pre-dive checks

top....

 

Battery Low

Cause

Overuse, or internal failure

Symptoms
Surface

Low Bat warning on handset. Solenoid not functioning. Cannot maintain set point

Dive

Low Bat warning on handset. Solenoid not functioning. Cannot maintain set point

Recovery action during Dive

Swap Masters (Slave should have more power)

Preventative action

Pre-Dive checks and measure battery voltage before dives. Replace before 5.5 volts reached or before big dive

top....

 


Battery Failure

Cause

Overuse or internal failure. Water in battery compartment

Symptoms
Surface

No handset.

Dive

No Handset. Solenoid not functioning. Cannot maintain set point.

Recovery action during Dive

Slave should take over. Abandon dive. If both fail then Bail out if you have no alternate means of monitoring PPO2

Preventative action

Pre-Dive checks and measure battery voltage before dives. Replace before 5.5 volts reached or before big dive

top....

 


Battery Bounce

Cause

Entering water by rolling backwards onto turtle shell. momentarily disconnects batteries

Symptoms
Surface

None

Dive

"Dive Now?" message a "Waiting for Data" messages

Recovery action during Dive

Urgent. Perform start up cycle. DO NOT CALIBRATE

Preventative action

Don't backwards roll from boats, and always immediately check handsets when entering water

top....

 


Handset Failure

Cause

Flooding, wiring or mechanical breakage

Symptoms
Surface

Blank screen

Dive

Blank screen

Recovery action during Dive

Other handset should take over. Abandon dive. Both handsets is almost certainly Battery flooding. Bail out

Preventative action

Protect handsets and check wiring during services

top....

 

Handsets Switched off

Cause

Forgot to put brain cells in today

Symptoms
Surface

Pre-dive check failure. Blank handsets. No pre-breath

Dive

No handsets.

Recovery action during Dive

Bail out or die

Preventative action

Pre-dive checks and basic monitoring of unit. Amazingly several people have killed or nearly killed themselves this way

top....

 


Loose Connection to Sensor

Cause

Corrosion or bad servicing

Symptoms
Surface

Intermittent "Out of Range" or "Failure" messages on a cell. Failure to calibrate

Dive

Intermittent "Out of Range" or "Failure" messages on a cell

Recovery action during Dive

Diluent flush to check other 2 sensors respond correctly. Consider bail out. Abandon dive

Preventative action

Service carefully

top....

 

Single Cell Failure

Cause

Exhausted or out of date cell. Cell Internal failure.

Symptoms
Surface

Intermittent "Out of Range" or "Failure" messages on a cell. Failure to calibrate

Dive

Intermittent "Out of Range" or "Failure" messages on a cell

Recovery action during Dive

Diluent flush to check which sensors respond correctly. Consider bail out. Abandon dive

Preventative action

Replace cells at correct intervals (every 12 months)

top....

 


Two Cell Failure

Cause

Exhausted or out of date cells. Insufficient ions to produce voltages representing high O2 above set point

Symptoms
Surface

Intermittent "Out of Range"  messages on a SINGLE cell (the good one). Failure to calibrate

Dive

Intermittent "Out of Range"  messages on a SINGLE cell (the good one). Failure to calibrate

Recovery action during Dive

Diluent flush to check which sensors respond correctly. Bail out. Abandon dive. Unit will maintain O2 limits on the 2 bad cells as they out vote the good one. O2 will be high

Preventative action

Replace cells at correct intervals (every 12 months). At start of dive drive cells above setpoint to ensure they can respond fully

top....

 


Condensation On Face

Cause

Moist warm saturated gas, condensating on objects in the gas flow

Symptoms
Surface

Normally none

Dive

Intermittent "Out of Range" or "Failure" messages on a cell.

Recovery action during Dive

Diluent flush to check which sensors respond correctly. Bail out. Abandon dive

Preventative action

Latest cells have PTFE face which is hydrophobic.  Insulate loop to lower condensation. Stop breathing or swap to Hammerhead

top....

 


Pressure Unequalisation

Cause

Unequal pressure on front and back of sensor cells during dive

Symptoms
Surface

None

Dive

Intermittent "Out of Range" or "Failure" messages on a cell.

Recovery action during Dive

Diluent flush to check which sensors respond correctly. Bail out. Abandon dive

Preventative action

Ensure gas flow to rear of cells. Make sure pressure equalisation holes are clear, and that the red caps have been modified (2mm hole). Consider multiple holes or grooving the black molex spacers to ensure gas flow

top....

 

Scrubber Exhausted

Cause

Overuse or improper storage. Out of date

Symptoms
Surface

Rapid breathing, headache. hypercapnia

Dive

Stuffiness, rapid breathing, confusion. Hypercapnia

Recovery action during Dive

Bail out

Preventative action

Change the scrubber every 3 hours or sooner

top....

 


Scrubber Bypass

Cause

Gas flows rapidly through a single path in the scrubber and CO2 is not removed

Symptoms
Surface

Rapid breathing, headache. hypercapnia

Dive

Stuffiness, rapid breathing, confusion. Hypercapnia

Recovery action during Dive

Bail out

Preventative action

Pack the scrubber unit correctly. Do not over or underfill

top....

 

Loop Flood

Cause

Puncture or structural failure in the loop

Symptoms
Surface

Pre-dive check failure. Unable to hold set point

Dive

Gurgling and other water in loop signs. breathing resistance

Recovery action during Dive

Bail out

Preventative action

Protect hoses with covers and service regularly. Pre-dive checks

top....

 


BC Failure

Cause

Puncture or structural failure of BC

Symptoms
Surface

Unable to inflate

Dive

Unable to inflate

Recovery action during Dive

Abandon dive. Use alternative buoyancy source. Ditch weight belt if needed

Preventative action

 Service regularly and test/inspect

top....

 


Harness Failure

Cause

Structural failure of component

Symptoms
Surface

Back unit swings and becomes loose

Dive

Unlikely as units weight is water supported

Recovery action during Dive

Tighten other straps. Abandon dive if unable to re-secure

Preventative action

Service regularly and test/inspect