Lots of people hark on about how rebreather can fail easily and kill you instantly. Here I've tried to list ALL the possible failure modes and how you can get out of them. All this is covered in your training and will become second nature. In fact ALL failures are possible to easily escape from providing you monitor the unit and do your pre dive checks
I am also only covering problems unique to the Inspiration as we still have all the normal diving problems to cope with but these are covered on lots of other sites. Please let me know if I've missed anything
There does seem to be a lot of things that can go wrong at first glance, but most of these will never happen if you do your pre-dive checks. Your training will teach you how to prevent and deal with these. If it didn't then please let me know
|
|
Oxygen Cylinder Empty
Oxygen Cylinder Switched Off
Oxygen First Stage Failure
Oxygen First Stage Over Pressure
Oxygen Hose Leaks
Oxygen Solenoid Stuck Open
Oxygen Solenoid Stuck Closed
Oxygen Manual Injector Failure
Wrong Gas in Oxygen cylinder
Diluent Cylinder Empty
Diluent Cylinder Switched Off
Diluent First Stage Failure
Diluent First Stage Over Pressure
Diluent Hose Leaks
Diluent Manual Injector Failure
Alternate Air Source Free Flow
Wrong Gas in Diluent cylinder
Battery Low
Battery Failure
Battery Bounce
Handset Failure
Loose Connection to Sensor
Handsets Switched off
Single Cell Failure
Two Cell Failure
Condensation On Face
Pressure Unequalisation
|
|
Oxygen Cylinder Empty
Cause
Tut, tut, Who forgot to fill that cylinder! Or diving with not enough O2 for the dive. Maybe a leak somewhere, but you notice bubbles on a rebreather
Symptoms
Surface
Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding. Oxygen contents gauge showing empty
Dive
Failure to hold set point. Low O2 Alarm sounding. Oxygen contents gauge showing empty
Recovery action during Dive
Urgent. Bail out to open circuit or diluent flush and fly unit in semi closed mode
Preventative action
Check the cylinders contents during the pre-dive checks
Oxygen Cylinder Switched OffCause
Lack of brain power and failure to do pre-dive checks. This should not happen, but it has claimed lives
Symptoms
Surface
Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding. Oxygen contents gauge showing empty
Dive
Failure to hold set point. Low O2 Alarm sounding. Oxygen contents gauge showing empty
Recovery action during Dive
Urgent. Open O2 valve, ready to bail out to open circuit or diluent flush and fly unit in semi closed mode
Preventative action
Check the cylinders contents during the pre-dive checks
Oxygen First Stage FailureCause
Wear or structural failure. Overpressure valve fitted may blow or unit may jam
Symptoms
Surface
Failure to calibrate. Failure to hold set point during pre-breathe. Low or high O2 Alarm Sounding. Oxygen contents gauge showing empty or audible air loss from cylinder
Dive
Failure to hold set point. Low or high O2 Alarm sounding. Oxygen contents gauge may show empty. Bubbles in water
Recovery action during Dive
Urgent. Bail out to open circuit or diluent flush and fly unit in semi closed mode
Preventative action
Pre-dive checks. Oxygen Interstage pressure checks when servicing
Oxygen First Stage Over PressureCause
Bad servicing, or wear of first stage
Symptoms
Surface
Only if battery low. Solenoid can fail to fire before low battery warning given. Hence Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding
Dive
Only if battery low. Solenoid can fail to fire before low battery warning given. Hence Failure to hold set point during pre-breathe. Low O2 Alarm Sounding
Recovery action during Dive
Urgent. Bail out to open circuit or diluent flush and fly unit in semi closed mode
Preventative action
Check interstage pressure during servicing and use fresh batteries
Oxygen Hose LeaksCause
Wear, bad servicing
Symptoms
Surface
Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding. Oxygen contents gauge showing low or audible air loss from cylinder
Dive
Failure to hold set point. Low O2 Alarm sounding. Oxygen contents gauge may show empty. Bubbles in water
Recovery action during Dive
Urgent. Bail out to open circuit or diluent flush and fly unit in semi closed mode
Preventative action
Pre-dive checks
Oxygen Solenoid Stuck OpenCause
Corrosion, Bad servicing, salt crystals or contaminates in unit. High Interstage pressure. Low Battery
Symptoms
Surface
Failure to calibrate. Failure to hold set point during pre-breathe. High O2 Alarm Sounding. Counter lungs full
Dive
Failure to hold set point. High O2 Alarm sounding. Excessive buoyancy. Can hear solenoid injecting at all times
Recovery action during Dive
Urgent. Close O2 valve. Bail out, or diluent flush. Option to fly manually using O2 valve or to go semi closed
Preventative action
Regular service. Lube and ensure solenoid clean, Check mesh filter above solenoid. Fresh Batteries
Oxygen Solenoid Stuck ClosedCause
Corrosion, Bad servicing, salt crystals or contaminates in unit. Low battery. High interstage pressure
Symptoms
Surface
Failure to calibrate. Failure to hold set point during pre-breathe. Low O2 Alarm Sounding.
Dive
Failure to hold set point. Low O2 Alarm sounding
Recovery action during Dive
Urgent. Fly unit manually using manual O2 injector. Consider bail out
Preventative action
Regular service. Lube and ensure solenoid clean, Check mesh filter above solenoid. Fresh batteries
Oxygen Manual Injector FailureCause
Bad maintenance. Failure to plug hose on properly
Symptoms
Surface
Failure of pre dive checks
Dive
Loss of gas from loop, flooding of loop.
Recovery action during Dive
Urgent. Reconnect Hose or rescrew injector down. Bail out if loop flooded
Preventative action
Pre-Dive checks
Wrong Gas in Oxygen cylinder
Cause
Nitrox fill or gas other than 100% oxygen
Symptoms
Surface
Failure to calibrate (maybe). failure to hold set point. Lungs full
Dive
Failure to hold set point (maybe), Excessive buoyancy and injector function
Recovery action during Dive
Bail out (you don't know what you are breathing)
Preventative action
ALWAYS analyse your gasses after a fill. You'd be amazed how many places don't give a 100% fill, or nowadays, how many air fills aren't
On these two fills one is 96% and the other 99.8%. I always analyse and label my gases myself. Never trust a shop
Diluent Cylinder Empty
Cause
Someone forgot to fill it, or a bad leak
Symptoms
Surface
Failure of pre-dive checks, Diluent contents gauge reads zero
Dive
Lung squeeze on descent, unable to inject diluent. Auto Air out not functional. Dry suit inflate not functional
Recovery action during Dive
Plug in a reserve gas supply. Inflate lungs with manual O2 inject if above 6m
Preventative action
Pre-dive checks
Diluent Cylinder Switched OffCause
Silly mistake
Symptoms
Surface
Failure of pre-dive checks, Diluent contents gauge reads zero
Dive
Lung squeeze on descent, unable to inject diluent. Auto Air out not functional. Dry suit inflate not functional
Recovery action during Dive
Open valve
Preventative action
Pre-dive checks
Diluent First Stage FailureCause
Wear or structural failure
Symptoms
Surface
Failure of pre-dive checks, Diluent contents gauge reads zero
Dive
Lung squeeze on descent, unable to inject diluent. Auto Air out not functional. Dry suit inflate not functional
Recovery action during Dive
Plug in a reserve gas supply. Inflate lungs with manual O2 inject if above 6m
Preventative action
Service correctly and Pre-dive checks
Diluent First Stage Over PressureCause
Wear or structural failure. Bad adjustment
Symptoms
Surface
Auto air free flow, BC inflation
Dive
Auto air free flow, Excessive buoyancy in BC
Recovery action during Dive
Shut down diluent valve. Manually operate when needed (Shouldn't need to surface). Consider bailout if alternate supply
Preventative action
Service correctly and pre-dive checks
Diluent Hose LeaksCause
Wear. Bad servicing
Symptoms
Surface
Failure of pre-dive checks. Audible gas escape. Diluent contents decreasing
Dive
Audible gas escape. Diluent contents decreasing
Recovery action during Dive
Abort dive
Preventative action
Pre-dive checks and servicing
Diluent Manual Injector FailureCause
Bad maintenance. Failure to plug hose on properly
Symptoms
Surface
Failure of pre dive checks
Dive
Loss of gas from loop, flooding of loop.
Recovery action during Dive
Urgent. Reconnect Hose or rescrew injector down. Bail out if loop flooded
Preventative action
Pre-Dive checks
Wrong Gas In Diluent Cylinder
Cause
Cylinder filled wrongly
Symptoms
Surface
None with normal pre-dive checks
Dive
Problems maintaining Setpoint during descent
Recovery action during Dive
Abandon dive, of connect alternate diluent source (Not likely to notice during dive)
Preventative action
Analyse ALL gasses prior to use. Once unit is calibrated you can check the diluent O2 content by doing a diluent flush. This should be added as part of the pre-dive tests
Alternate Air Source Free FlowCause
Dirt or high diluent interstage pressure
Symptoms
Surface
Failure of pre-dive checks. Audible gas loss
Dive
Audible gas loss and bubbles
Recovery action during Dive
Disconnect Auto air, or try shaking to reseat things. Consider aborting dive
Preventative action
Service equipment and pre-dive checks
Battery Low
Cause
Overuse, or internal failure
Symptoms
Surface
Low Bat warning on handset. Solenoid not functioning. Cannot maintain set point
Dive
Low Bat warning on handset. Solenoid not functioning. Cannot maintain set point
Recovery action during Dive
Swap Masters (Slave should have more power)
Preventative action
Pre-Dive checks and measure battery voltage before dives. Replace before 5.5 volts reached or before big dive
Battery FailureCause
Overuse or internal failure. Water in battery compartment
Symptoms
Surface
No handset.
Dive
No Handset. Solenoid not functioning. Cannot maintain set point.
Recovery action during Dive
Slave should take over. Abandon dive. If both fail then Bail out if you have no alternate means of monitoring PPO2
Preventative action
Pre-Dive checks and measure battery voltage before dives. Replace before 5.5 volts reached or before big dive
Battery BounceCause
Entering water by rolling backwards onto turtle shell. momentarily disconnects batteries
Symptoms
Surface
None
Dive
"Dive Now?" message a "Waiting for Data" messages
Recovery action during Dive
Urgent. Perform start up cycle. DO NOT CALIBRATE
Preventative action
Don't backwards roll from boats, and always immediately check handsets when entering water
Handset FailureCause
Flooding, wiring or mechanical breakage
Symptoms
Surface
Blank screen
Dive
Blank screen
Recovery action during Dive
Other handset should take over. Abandon dive. Both handsets is almost certainly Battery flooding. Bail out
Preventative action
Protect handsets and check wiring during services
Handsets Switched off
Cause
Forgot to put brain cells in today
Symptoms
Surface
Pre-dive check failure. Blank handsets. No pre-breath
Dive
No handsets.
Recovery action during Dive
Bail out or die
Preventative action
Pre-dive checks and basic monitoring of unit. Amazingly several people have killed or nearly killed themselves this way
Loose Connection to SensorCause
Corrosion or bad servicing
Symptoms
Surface
Intermittent "Out of Range" or "Failure" messages on a cell. Failure to calibrate
Dive
Intermittent "Out of Range" or "Failure" messages on a cell
Recovery action during Dive
Diluent flush to check other 2 sensors respond correctly. Consider bail out. Abandon dive
Preventative action
Service carefully
Single Cell Failure
Cause
Exhausted or out of date cell. Cell Internal failure.
Symptoms
Surface
Intermittent "Out of Range" or "Failure" messages on a cell. Failure to calibrate
Dive
Intermittent "Out of Range" or "Failure" messages on a cell
Recovery action during Dive
Diluent flush to check which sensors respond correctly. Consider bail out. Abandon dive
Preventative action
Replace cells at correct intervals (every 12 months)
Two Cell FailureCause
Exhausted or out of date cells. Insufficient ions to produce voltages representing high O2 above set point
Symptoms
Surface
Intermittent "Out of Range" messages on a SINGLE cell (the good one). Failure to calibrate
Dive
Intermittent "Out of Range" messages on a SINGLE cell (the good one). Failure to calibrate
Recovery action during Dive
Diluent flush to check which sensors respond correctly. Bail out. Abandon dive. Unit will maintain O2 limits on the 2 bad cells as they out vote the good one. O2 will be high
Preventative action
Replace cells at correct intervals (every 12 months). At start of dive drive cells above setpoint to ensure they can respond fully
Condensation On FaceCause
Moist warm saturated gas, condensating on objects in the gas flow
Symptoms
Surface
Normally none
Dive
Intermittent "Out of Range" or "Failure" messages on a cell.
Recovery action during Dive
Diluent flush to check which sensors respond correctly. Bail out. Abandon dive
Preventative action
Latest cells have PTFE face which is hydrophobic. Insulate loop to lower condensation. Stop breathing or swap to Hammerhead
Pressure UnequalisationCause
Unequal pressure on front and back of sensor cells during dive
Symptoms
Surface
None
Dive
Intermittent "Out of Range" or "Failure" messages on a cell.
Recovery action during Dive
Diluent flush to check which sensors respond correctly. Bail out. Abandon dive
Preventative action
Ensure gas flow to rear of cells. Make sure pressure equalisation holes are clear, and that the red caps have been modified (2mm hole). Consider multiple holes or grooving the black molex spacers to ensure gas flow
Scrubber Exhausted
Cause
Overuse or improper storage. Out of date
Symptoms
Surface
Rapid breathing, headache. hypercapnia
Dive
Stuffiness, rapid breathing, confusion. Hypercapnia
Recovery action during Dive
Bail out
Preventative action
Change the scrubber every 3 hours or sooner
Scrubber BypassCause
Gas flows rapidly through a single path in the scrubber and CO2 is not removed
Symptoms
Surface
Rapid breathing, headache. hypercapnia
Dive
Stuffiness, rapid breathing, confusion. Hypercapnia
Recovery action during Dive
Bail out
Preventative action
Pack the scrubber unit correctly. Do not over or underfill
Loop Flood
Cause
Puncture or structural failure in the loop
Symptoms
Surface
Pre-dive check failure. Unable to hold set point
Dive
Gurgling and other water in loop signs. breathing resistance
Recovery action during Dive
Bail out
Preventative action
Protect hoses with covers and service regularly. Pre-dive checks
BC FailureCause
Puncture or structural failure of BC
Symptoms
Surface
Unable to inflate
Dive
Unable to inflate
Recovery action during Dive
Abandon dive. Use alternative buoyancy source. Ditch weight belt if needed
Preventative action
Service regularly and test/inspect
Harness FailureCause
Structural failure of component
Symptoms
Surface
Back unit swings and becomes loose
Dive
Unlikely as units weight is water supported
Recovery action during Dive
Tighten other straps. Abandon dive if unable to re-secure
Preventative action
Service regularly and test/inspect